Based on their starting principles, single-phase induction motors (single-phase asynchronous motors) are primarily categorized into two types: split-phase and shaded-pole. Split-phase motors are further subdivided into capacitor-split-phase and resistance-split-phase types, depending on whether a capacitor or a resistor is used to achieve phase shifting. Capacitor-split-phase motors can be further classified-based on the capacitor's function within the circuit-into capacitor-start, capacitor-run, and capacitor-start-and-run types.
Split-phase single-phase motors utilize a capacitor or resistor connected in series with an inductive starting winding to induce a phase shift, thereby creating a phase difference between the currents in the starting winding and the running winding. In capacitor-split-phase motors, the phase-shifting effect of the capacitor is significant; by connecting a capacitor of appropriate capacitance in series with the starting winding, the phase difference between the currents in the two windings can approach 90°. This results in a resultant rotating magnetic field that is nearly circular, yielding high starting torque combined with relatively low starting current. In contrast, the starting winding of a resistance-split-phase motor consists of fewer turns of thinner wire, resulting in lower reactance and higher resistance compared to the running winding; consequently, the resultant magnetic field is highly elliptical, and the starting torque is low.
Capacitor-split-phase motors fall into three main categories based on the specific function of the capacitor in the circuit. In capacitor-start motors, the starting winding and starting capacitor are connected in series during startup; once the rotor speed reaches 70%–80% of its rated value, a centrifugal switch automatically disconnects the starting winding and capacitor, leaving the main winding to operate alone. These motors offer high starting torque (typically 2–4 times the rated torque or higher) and relatively low starting current, making them suitable for applications requiring startup under load. In capacitor-run motors, the starting winding remains connected in series with a low-capacitance capacitor during both startup and continuous operation; while the starting torque is lower, these motors offer superior operating performance (such as power factor and efficiency), smooth operation, and low noise levels, making them widely used in appliances like electric fans, washing machines, and air conditioner blowers. Capacitor-start, capacitor-run motors utilize two capacitors: a high-capacitance starting capacitor and a low-capacitance running capacitor. During startup, the two capacitors operate in parallel; once the motor reaches the set speed, a centrifugal switch disconnects the starting capacitor, leaving only the running capacitor and the starting winding engaged for operation. This configuration combines the advantages of high starting torque and superior running performance.
The starting winding of a resistance-split-phase single-phase motor is typically designed for short-term duty; it is disconnected by a centrifugal switch after startup, leaving the main (running) winding to sustain operation. Due to its relatively low starting torque, this type of motor is suitable only for applications involving no-load or light-load starts.
Shaded-pole single-phase motors are constructed by embedding a short-circuited copper ring or coil (shading coil) around a portion of the stator poles. When single-phase alternating current flows through the stator winding, the magnetic flux passing through the shading ring lags in phase behind the main flux, thereby generating a resultant magnetic field that is spatially offset and phase-shifted-effectively a rotating magnetic field with high ellipticity. These motors have a fixed direction of rotation (from the unshaded pole section toward the shaded pole section) and feature the simplest structure, lowest cost, and easiest maintenance; however, they offer low power output, minimal starting torque, and low efficiency, making them suitable for applications such as small blowers and electric fans.