When single-phase alternating current is supplied to the main winding of a single-phase AC motor, a pulsating magnetic field is generated; this field can be decomposed into two rotating magnetic fields of equal magnitude but opposite direction, resulting in a net starting torque of zero and preventing the motor from self-starting. To generate starting torque, a starting winding-spatially orthogonal to the main winding-is added to the stator, with a high-capacity AC electrolytic capacitor connected in series within its circuit.
Due to the characteristics of the capacitor, the current in the starting winding leads its terminal voltage in phase, whereas the current in the main winding lags the supply voltage; this causes the starting winding current to lead the main winding current by a significant phase angle (designed to be close to 90°). Supplying currents with a phase difference of nearly 90° to these two spatially orthogonal windings creates an elliptical or nearly circular rotating magnetic field in the motor's air gap.
This rotating magnetic field cuts across the rotor bars, inducing current and generating electromagnetic torque that drives the rotor to spin. When the rotor speed reaches 70–80% of its rated speed, a centrifugal switch automatically opens, disconnecting the starting winding and capacitor from the power supply; thereafter, the motor continues to operate powered solely by the main winding.